Laminated sheets based on phenolic resins and cellulosic paper

Laminate type

Composition

Operating temperature range, оС

Applications and distinguishing characteristics

Dimensions

PF CP 201

Cellulosic
paper,

phenolic resins

from - 65 to + 120

Mechanical applications. Mechanical properties better than other PF CP types. Poor electrical properties under normal humidity. Also available in hot-punching versions.

Sheets size:

(1000×2450)±20 mm

(1000×1220)±20 мм

Thickness: 0,1-100,0

PF CP 202

from - 65 to + 120

High-voltage applications at power frequencies. High electric strength in oil. Good electric strength in air under normal humidity.

Sheets size:

(1050×2450)±20 mm

(1050×1220)±20 мм

Thickness: 1,0-100,0

PF CP 203

from - 65 to + 120

Mechanical and electrical applications. Good electrical properties under normal humidity. Also available in cold or hot-punching versions.

Sheets size:

(1000×2450)±20 mm

(1000×1220)±20 мм

Thickness: 0,4-4,0

PROPERTIES

IEC 60893-3-4

PF CP 201

PF CP 202

PF CP 203

Property

Test method

Unit

Minimum
or
maximum

Values

Requirement

Typical

Requirement

Typical

Requirement

Typical

Flexural strength

ISO 178

MPa

minimum

135

135

120

160

120

130

Electrical strength at 90°C in oil perpendicular to laminations
(Thickness: 1,5 mm)

IEC 60243-1

kV/mm

minimum

-

8,0

14,5

20

6,7

13,5

Breakdown voltage at 90°C in oil parallel to laminations

IEC 60243-1

kV

minimum

-

30

60

60

15

30

Insulating resistance after immersion in water

IEC 60167

minimum

-

1×102

-

1×102

5×101

1×102

Water absorption (Thickness: 1,5 mm)

ISO 62

mg

maximum

19

8,0

19

6,0

19

7

Listed in the table are informational. On this basis, claims for quality can not be justified