COTTON CLOTH MOULDED TUBES AND RODS

TUBES PF CC 31, PF CC 32, PF CC 3
RODS PF CC 41, PF CC 42, PF CC 43

 


Round laminated moulded tubes

Types

Composition

Operating temperature range, оС

Applications and distinguishing characteristics

Dimensions

PF CC 31

Woven cotton cloth,
phenolic resins

from - 60 to + 120

Mechanical and electrical applications, fine weave

Nominal
diameters, mm

7,05 х 18,5

7,05 х 21,5

10,0 х 21,5

10,0 х 25,0

10,0 х 28,0

12,5 х 24,5

14,3 х 28,0

15,5 х 26,5

17,5 х 32,5

Length - not less
200 mm

PF CC 32

from - 60 to + 120

Similar CC to type PF CC 31, but of coarse weave.

PF CC 33

from - 60 to + 120

Similar to type PF CC 31, but of very coarse weave


Properties

IEC 61212-3-2

PF CC 31

PF CC 32

PF CC 33

Property

Test method

Unit

Minimum
or
maximum

Values

Standard

Typical

Standard

Typical

Standard

Typical

Flexural strength perpendicular to laminations

ISO 178

MPa

minimum

80

120

80

120

80

120

Axial compressive strength

ISO 604

MPa

minimum

100

180

100

180

100

180

Cohesion between layers

IEC 61212-2

MPa

minimum

90

200

90

200

90

Breakdown voltage at 90°C in oil parallel to laminations

IEC 60243-1

kV

minimum

5

12

5

12

5

200

Electrical strength at 90°C in oil perpendicular to laminations
(wall thickness =3mm),

IEC 60243-1

kV/mm

minimum

1,6

2,5

1,6

2,5

1,6

2,5

Insulating resistance after immersion in water

IEC 60167

minimum

10

1×102

5

1×102

1

50

Termal endurance

IEC 60216-1

ISO 178

TI

minimum

120

120

120

Water absorption

ISO 62

mg/cm2

maximum

5

2

6

2,5

8

2,5

Density

ISO 1183-1

g/cm3

Range

1,2-1,4

1,2-1,4

1,2-1,4

Listed in the table are informational. On this basis, claims for quality can not be justified.