Types |
Composition |
Operating temperature range, оС |
Applications and distinguishing characteristics |
Dimensions |
PF CP 21 |
Cellulosic paper, phenolic resins |
from - 60 to + 120 |
Mechanical and low voltage electrical applications. Good electrical properties when exposed to normal relative humidity. |
Inner diameter:
|
PF CP 22 |
from - 60 to + 120 |
High voltage electrical applications at power CP frequencies. High electric strength in oil. |
IEC 61212-3-1 |
PF CP 21 |
PF CP 22 |
|||||
Property |
Test method |
Unit |
Minimum
|
Values |
|||
Requirement |
Typical |
Requirement |
Typical |
||||
Flexural strength perpendicular to laminations |
ISO 178 |
MPa |
minimum |
100 |
150 |
100 |
150 |
Axial compressive strength |
ISO 604 |
MPa |
minimum |
100 |
110 |
80 |
90 |
Cohesion between layers |
IEC 61212-2 |
MPa |
minimum |
70 |
70 |
||
Breakdown voltage at 90°C in oil parallel to laminations |
IEC 60243-1 |
kV |
minimum |
10 |
15 |
15 |
20 |
Electrical strength at 90°C in oil perpendicular to laminations
|
IEC 60243-1 |
kV/mm |
minimum |
- |
10 |
10,8 |
12 |
Insulating resistance after immersion in water |
IEC 60167 |
MΏ |
minimum |
1 |
1 |
1 |
1 |
Termal endurance |
IEC 60216-1 ISO 178 |
TI |
minimum |
120 |
120 |
||
Water absorption |
ISO 62 |
mg/cm2 |
maximum |
10 |
6 |
10 |
6 |
Density |
ISO 1183-1 |
g/cm3 |
Range |
1,10-1,20 |
1,05-1,15 |
Listed in the table are informational. On this basis, claims for quality can not be justified.